If there is conductive hearing loss, it is likely to be louder in the affected ear if there is sensorineural hearing loss, it will be quieter in the affected ear. The patient is then asked if the sound is localised in the centre of the head or whether it is louder in either ear. Additionally, the tuning fork is placed on the forehead. If they cannot, there is conductive hearing loss in that ear. When the patient can no longer feel/hear the vibration, the tuning fork is held in front of the ear the patient should once more be able to hear a ringing sound. In this test, a vibrating tuning fork is placed behind the ear, on the mastoid process. In order to determine what kind of hearing loss is present, a bone conduction hearing test is administered. Weber and Rinne Ī complete hearing evaluation involves several other tests as well. Scientists suggest that the hearing test using a mobile application can be used to identify hearing pathologies and also for hearing screening tests. ĭespite possible errors in the results of diagnostics, the undoubted advantages of hearing testing with a special application or hearing aid application include the ability to do the hearing test without assistance and the availability of hearing testing. noise masking effect of tone signals Īdvantages of the audiometry conducted with a specialized application or hearing aid application include availability and possibility to do the hearing test without assistance.heterogeneity of parameters of sound-recording systems in smartphones and tablets, and also headphones or headsets.sound-proofing of the room where hearing test is held.


In-situ audiometry using mobile applications

There is also a high frequency version of the test which tests frequencies over 8000Hz to 16000Hz which may be employed in special circumstances. On an audiogram an "x" plot represents the softest threshold heard at each specific frequency in the left ear, and an "o" plot represents the softest threshold heard at each specific frequency in the right ear. The result of the test is an audiogram diagram which plots a person's hearing sensitivity at the tested frequencies. The test is conducted in a sound booth using either a pair of foam inserts or supraural headphones connected to an external audiometer. The standard and most common type of hearing test is pure tone audiometry, which measures the air and bone conduction thresholds for each ear in a set of 8 standard frequencies from 250Hz to 8000Hz.

The most common reasons to develop hearing loss due to genetic disorder, ageing problems, exposure to noise pollution, infections, birth complications, trauma to the ear, and certain medications or toxins.
#TUNING FORK HEARING TEST FREE#
Prior to the hearing test itself, the ears of the client are usually examined with an otoscope to make sure they are free of wax, that the eardrum is intact, the ears are not infected, and the middle ear is free of fluid (indicating middle ear infection). 3 In-situ audiometry using mobile applications.